Email

info@bestbullenergy.com

WhatsApp

+8613534284656

Velonix DC charger 60KW-320KW DC-Velonix006

Explore Velonix 60–320 kW DC fast chargers with a 10-inch display
Send Inquiry
Description
Argument
Products Description

60–320 kW DC Fast Charger

DC Charging for Commercial Sites, Electric Trucks and Bus Fleets

The Velonix DC fast charger series offers rated power configurations from 60 kW to 320 kW, a 150–1000 V DC output range and a 10-inch charging display. Designed for commercial EV charging and fleet applications, it combines a clear operating interface, flexible connector options and OCPP connectivity in a floor-standing cabinet.

For the 320 kW configuration, a single connector can deliver up to 240 kW when operating alone. When both connectors operate simultaneously, each can deliver up to 160 kW, providing a combined output of up to 320 kW.

60–320 kW Power Options | 10-Inch Display | CCS2 Standard | OCPP Connectivity

[Request a Quote]  [Contact Velonix]

Charging Power for Single- and Dual-Vehicle Operation

Plan charging around your vehicles and operating schedule. The 320 kW model supports two operating modes:

Operating ModeMaximum Charging Power
Single connector operatingUp to 240 kW
Two connectors operating simultaneouslyUp to 160 kW per connector
Combined dual-connector outputUp to 320 kW

Actual output depends on vehicle battery voltage, charging acceptance, charger current limits and site power availability. Lower-power models have their own output limits.

Key Features

150–1000 V DC Output Range

A wide output voltage range supports charging projects involving different EV battery platforms. Connector compatibility, output current and vehicle charging requirements should be matched when selecting the model.

10-Inch Charging Display

The 10-inch display provides a dedicated interface for charging operation and status information. A clear front-panel layout helps drivers access the charging controls, while green, blue and red indicators show charger status.

Connector Options for Different Markets

CCS2 is the standard connector, with CCS1, CHAdeMO and NACS available as options. One- and two-connector configurations can be specified according to the model and project requirements.

OCPP Backend Connectivity

OCPP 1.6J and Ethernet connectivity support integration with compatible charging management platforms. Optional 4G connectivity and OCPP 2.0.1 are available for projects with additional communication requirements.

User Access Options

RFID authentication supports controlled charging access. App-based access and credit card functions can be customized according to the selected hardware and backend integration.

IP54 and IK10 Enclosure

The charger features an IP54 enclosure and IK10 impact protection. Air cooling supports thermal management, with a specified operating temperature range of −30°C to +50°C.

Integrated Electrical Protection

Protection functions include overvoltage, undervoltage, overcurrent, short-circuit, overtemperature, ground-fault and surge protection, together with residual current protection and internal fuses.

Applications

Electric Truck Charging
Configure DC charging for compatible electric trucks at logistics centers, distribution hubs and fleet depots. Match charger output to vehicle requirements and daily charging windows.

Electric Bus Charging
Support depot charging plans based on bus schedules, battery capacity and available electrical infrastructure.

Public EV Charging Stations
Provide single- or dual-vehicle DC charging at public charging locations and commercial parking facilities.

Commercial Fleet Charging
Select power ratings, connector combinations and access methods to suit company vehicles and managed fleet operations.

Technical Specifications

ParameterSpecification
Rated power range60–320 kW, depending on model
Single-connector output — 320 kW modelUp to 240 kW when one connector operates
Dual-connector output — 320 kW modelUp to 2 × 160 kW simultaneously
Input connectionThree-phase, 3P + N + PE
Input voltage400 V AC ±10%
Input frequency50 / 60 Hz
DC output voltage150–1000 V DC
Power factor≥0.98
Input current harmonic distortion — THDi≤5%
Charging display10-inch display
Charging interfaces1 or 2, depending on configuration
Standard connectorCCS2
Optional connectorsCCS1 / CHAdeMO / NACS
AuthenticationRFID, ISO/IEC 14443
Optional access and paymentApp / credit card customization
Energy meteringDC meter, 1% accuracy
Network connectionEthernet; 4G optional
Vehicle communicationISO 15118 / DIN 70121
Backend protocolOCPP 1.6J; OCPP 2.0.1 optional
LED indicatorsGreen / blue / red
Ingress protectionIP54
Impact protectionIK10
CoolingAir cooling
Operating temperature−30°C to +50°C
Storage temperature−40°C to +75°C
Operating humidityMaximum 93% RH, non-condensing
Operating altitude≤2,000 m

Specifications and optional functions are subject to the selected model. Contact Velonix for model-specific output limits, dimensions and certification documentation.

OEM/ODM Support

Configure your commercial EV charging station around your market and installation requirements. Velonix supports discussions covering power selection, connector combinations, cabinet branding, network connectivity and authentication options.

Frequently Asked Questions

What is the maximum power when only one vehicle is charging?

For the 320 kW model, one connector can deliver up to 240 kW when operating alone, subject to vehicle acceptance and the charger’s voltage and current limits.

What happens when two vehicles charge simultaneously?

The 320 kW model supports up to 160 kW from each connector at the same time, for a combined output of up to 320 kW. Actual power depends on the charging demand of each vehicle.

What display does the charger use?

The charger uses a 10-inch display for charging operation and status information.

Can the charger serve electric trucks and buses?

Yes, for compatible vehicles. Provide the vehicle models, battery voltage range and charging interface so Velonix can confirm the appropriate configuration.

Can it connect to our charging management platform?

The charger supports OCPP 1.6J, with OCPP 2.0.1 optional. Share your platform requirements so the integration scope can be confirmed.

Discuss Your Charging Project

Send us your installation country, vehicle models, required power, connector preferences and expected quantity. Our team will help you select a configuration for your charging site or fleet depot.



Tags:

Technical parameter

Leave Your Message


Leave a message