Email

info@bestbullenergy.com

WhatsApp

+8613534284656

100kwh/90kw mobile ev charge station

Velonix Mobile Energy Storage + DC Fast Charging SystemConfiguration: 100 kWh ba
Send Inquiry
Description
Argument
Products Description

Velonix Mobile Energy Storage + DC Fast Charging System

Configuration: 100 kWh battery + 90 kW DC output (All-in-one)

1) System Overview

The Velonix 100 kWh / 90 kW unit is an integrated mobile energy storage charging system that combines LFP battery storage + PCS/EMS + DC fast charging in one compact cabinet. It is designed for off-grid / weak-grid scenarios, temporary charging deployments, fleet support, and emergency power applications.


2) Key Specifications

Energy Storage

  • Battery Capacity (Nominal): 100 kWh

  • Battery Chemistry: LFP (LiFePO₄)

  • Battery Management: Integrated BMS (cell monitoring, balancing, protections, alarms)

DC Fast Charging Output

  • Rated Output Power: 90 kW (DC)

  • Output Voltage Range: 200–750 V DC (typical EV range; can be configured)

  • Max Output Current: Up to 125 A (depends on voltage / connector configuration)

  • Charging Interface: Configurable (CCS2 / CCS1 / NACS / GB/T / CHAdeMO)

  • Number of Guns: Single / Dual (optional, project-based)

AC Input / Charging (Optional)

  • AC Charging Input: Configurable (single/three-phase options per project)

  • Charging Source: Grid / Generator / PV (optional integration)

System Efficiency

  • Overall System Efficiency: ≥95% (typical for power electronics path; project-dependent)

Cooling & Thermal Management

  • Cooling Method: Forced air (fan cooling) (typical for this size)

Environmental & Protection

  • Protection Grade: IP54 (typical for outdoor cabinet applications)

  • Operating Temperature: -20°C to +55°C (configurable)

  • Operating Altitude: ≤2000 m (typical)

Monitoring & Communication (Optional)

  • Connectivity: Wi-Fi / Ethernet / 4G (optional)

  • Remote Monitoring: EMS dashboard (SOC, power, alarms, logs)

  • Protocol Options: OCPP / Modbus (optional, based on operation mode)

Safety Functions (Typical)

  • Over/under voltage protection

  • Overcurrent & short-circuit protection

  • Overtemperature protection (battery + power modules)

  • Insulation monitoring / grounding protection

  • Emergency stop & fault isolation

  • Event logging & alarm history

Warranty

  • Standard Warranty: 3 years (configurable to project terms)


3) Typical Application Scenarios

  1. Fleet Depot Support / Peak Charging

  • Buffer charging for fleet vehicles when site power is limited

  • Reduce peak demand and avoid transformer upgrades

  1. Off-Grid / Remote Charging

  • Temporary charging in remote areas, mining sites, ports, logistics yards

  • Works with generator or renewable charging inputs

  1. Emergency Response & Backup Power

  • Power restoration for critical loads + EV charging support during outages

  • Rapid deployment with minimal installation

  1. Construction Sites

  • Power for site operations and charging for EV work vehicles

  • Lower noise and fuel logistics vs. diesel-only solutions

  1. Events / Temporary Venues

  • Quiet, stable energy supply + optional EV charging for staff and logistics


Tags: mobile ev charge station

Technical parameter

Leave Your Message


Leave a message